Model | ACT-1000N | ACT-1000N-V300 |
---|---|---|
Capacity | 1000N | |
Resolution | 1N | |
Accuracy | +/-0.5% F.S +/-1digit | |
Unit | N, kgf ,lbf (*1) | |
Sampling rate | 2000Hz | |
Safe overload rating | Approx. 150% F.S. | |
Overload warning | 110% or less | |
Measuring speed0 | 10/25/50/100 mm/min(Choose from 4 steps) | 25/50/100/300 mm/min(Choose from 4 step) |
Stroke | Approx.50mm | |
Allowable sample diameter | Terminal side: Slit width 1~8mm (*2) | |
Harness side: Aperture width 1~8mm (*2) | ||
Allowable sample length | 100mm or more | |
Mode | BREAK/KEEP mode | |
Number of registered test condition | 26 patterns(A~Z) | |
Output | USB/RS232C/pass or fail decision signal (OK/NG) | |
Security lock | Emergency stop button and Overload prevention (at the power on) | |
Power supply | AC100~240V | |
Weight | Approx.11kg | |
Size | W400*D240*H150 | |
Operating environment | Temperature :0~40 degree Celsius Humidity:20~80%RH | |
Conformance Testing | -UL 486A-486B(2013) “ Standard for Safety for Wire Connectors, 9.3.4 Pullout test”-IEC 60512-16-4(2008) ” Connectors for electronic equipment – Tests and measurements- Part 16-4: Mechanical tests on contacts and terminations – Test 16d: Tensile strength (crimped connections)”-JIS C2805(2010) “Crimp-type terminal lugs for copper conductors.” |
|
Accessory | Software, USB cable, Power cord, Inspection Certificate |
Selectable Test Mode: BREAK mode and KEEP mode
2 modes are selectable. BREAK mode: In this mode, you can perform destructive test.
KEEP mode: In this mode, you can perform nondestructive test to apply specific force in set time.
The OK/NG (Pass/Fail) result is clear to see in both test modes.
Storable 26 Test Patterns
The tester is capable of saving up to 26 test patterns as presetting.
You can immediately recall each pattern. Smooth test condition change is possible.
Easy Data Management
ACT-1000N includes the software. It is ideal for checking the result such as force value, OK/NG (Pass/Fail) result and each test condition.
Also, the statistics such as No.of OK/ NG/ Whole values, average, etc. is automatically calculated. It is also possible for each test pattern.
[Performable Test According to Standard]
- UL 486A-486B(2013) “ Standard for Safety for Wire Connectors 9.3.4 Pullout test” .
Quý khách có nhu cầu vui lòng liên hệ Mr Khoa 0987.998.477 hoặc e-mail: sales@shinzo.com.vn
THIẾT BỊ ĐO LỰC MOMEN XOẮN TOHNICHI - Torque...
Chi tiếtMaker TOHNICHI - Made in Japan. T-S Dial Indicating...
Chi tiếtTUA VÍT XOẮN MOMEN ĐIỀU CHỈNH LỰC TOHNICHI...
Chi tiếtMaker: TOHNICHI, Made in Japan. DB12N4-S Dial Indicating...
Chi tiếtA vertical & horizontal motorized stand for force gages. One...
Chi tiếtDigital force gauge AD-FG series that enhances standard...
Chi tiếtWith reinforced plastic body, light, small measuring...
Chi tiếtMaker: TOHNICHI, Made in Japan. ATG / BTG Torque Gauge...
Chi tiếtMaker: TOHNICHI, Made in Japan. ATG / BTG Torque Gauge...
Chi tiếtWith reinforced plastic body, light, small measuring...
Chi tiếtWith reinforced plastic body, light, small measuring...
Chi tiếtMaker: TOHNICHI, Made in Japan. ATG / BTG Torque Gauge...
Chi tiếtTHIẾT BỊ ĐO LỰC MOMEN XOẮN TOHNICHI - Torque...
Chi tiết